AU-HA05 Explosion-Proof LED Highbay | Eye Lighting Australia
IECEx & ATEX Certified

AU-HA05 LED Explosion-Proof Highbay Light

Zone 2 and C1D2 Hazardous Areas

AU-HA05 explosion-proof LED highbay lighting delivers certified performance for Zone 2, Zone 20, 21 and 22 hazardous areas, as well as Class I Division 2 environments. Featuring up to 140 lm/W efficacy, six mounting configurations, and a power range from 30W to 240W producing up to 33,600 lumens, this luminaire replaces HPS fixtures up to 700W across oil refineries, chemical plants, mining operations, and marine installations throughout Australia.

Zone 2 Zone 21 Zone 22 C1D2 Marine
AU-HA05 LED Explosion-Proof Highbay Light ceiling mount for Zone 2 and C1D2 hazardous areas
140 lm/W
Efficacy
IP66
Protection Rating
33,600 lm
Maximum Output
6 Options
Mounting Configs
5 Years
Warranty

One Certified Platform, Every Configuration

Six Mounting Options

Ceiling, pendant, wall bracket, trunnion, 25 degree stanchion, and 90 degree stanchion. One product family covers every installation requirement across the entire site. One certification chain, one set of spares.

30W to 240W Range

Nine power configurations delivering 4,200 to 33,600 lumens at up to 140 lm/W. Replaces HPS fixtures up to 700W, eliminating re-strike delays and cutting energy consumption significantly.

Marine Grade Construction

Copper-free aluminium alloy housing with C4 corrosion resistance. Stainless steel hardware with anti-corrosion treatment. UL1598A Marine certified for coastal and offshore environments.

Flip-Type Access

Hinged housing provides direct access to internal components during maintenance without removing the fixture from its mount. Shorter service windows and less time working in the classified area.

Simplified Installation Across Entire Sites

Hazardous area projects rarely involve a single mounting requirement. A refinery might need pendant highbays over a processing floor, wall mounted fixtures along access corridors, and stanchion units on external structures. Specifying different product families for each configuration means separate certification documents, separate spare parts inventories, and separate compliance records.

The AU-HA05 eliminates that complexity. Loop-in and loop-out terminal blocks reduce cable runs across multi-fixture installations, cutting both material and labour costs. Four conduit holes on ceiling, bracket, and wall mounting options allow interconnection between luminaires, simplifying wiring across the full installation.

AU-HA05 LED Explosion-Proof Highbay 25 degree stanchion mount configuration

AU-HA05 Model Variants

AU-HA05-050

50W Compact + Emergency

The 50W model is available with built in emergency backup, providing 1,620 lumens for 90 minutes or 720 lumens for 3 hours during power loss.

  • Power 50W
  • Luminous Flux 7,000 lm
  • Emergency 90 min / 3 hr

AU-HA05-120

120W Mid-Range

Mid-range output for general hazardous area lighting across processing areas, conveyor tunnels, and industrial facilities requiring certified illumination.

  • Power 120W
  • Luminous Flux 16,800 lm
  • Efficacy 140 lm/W

AU-HA05-240

240W High Output

Maximum output for large open hazardous areas. Replaces HPS 700W fixtures, delivering the same illumination at a fraction of the energy consumption.

  • Power 240W
  • Luminous Flux 33,600 lm
  • Replaces HPS 700W

AU-HA05 Technical Data

Power Options 30W / 50W / 75W / 100W / 120W / 150W / 180W / 200W / 240W (±5%)
Input Voltage ATEX/IECEx: 100-277Vac, 50/60Hz | NEC/CEC: 100-277Vac, 277-480Vac, 50/60Hz
Luminous Flux 4,200 lm (30W) to 33,600 lm (240W) ±10%
Efficacy Up to 140 lm/W (4000K Ra70)
Colour Temperature 5000K standard (2000K, 2200K, 2500K, 2700K, 3000K, 3500K, 4000K, 4500K, 5700K, 6500K optional)
CRI Ra70 / Ra80 / Ra90
Coloured LED Options Red, Green, Blue, Amber
Beam Angles Type I, Type III, Type V distribution
Dimming 1-10V, DALI, or Non-dimmable
IP Rating IP66
Impact Resistance IK08
Operating Temperature -40°C to +65°C
Housing Material Marine Grade Copper-Free Aluminium Alloy (C4 Corrosion Resistant)
Emergency Option AU-HA05-050: 1,620 lm for 90 min or 720 lm for 3 hours
IECEx Certification Ex nR IIC T6/T5 Gc / Ex tb IIIC T80°C/T95°C Db IP66
ATEX Certification II 3G Ex nR IIC T6/T5 Gc / II 2D Ex tb IIIC T80°C/T95°C Db IP66
NEC/CEC Class I Div 2 (A,B,C,D) / Class II Div 1 (E,F,G) / Class II Div 2 (F,G) / Class III / UL1598A Marine
Warranty 5 Years

Six Mounting Configurations

Ceiling Mount

323x300x186mm (30-100W)
380x201mm (120-240W)
4 conduit holes

Pendant Mount

300x230mm (30-100W)
380x246mm (120-240W)
1 conduit hole

Wall Bracket

442x300x240mm (30-100W)
482x380x256mm (120-240W)
4 conduit holes

25° Stanchion

400x300x280mm (30-100W)
443x380x312mm (120-240W)
1 conduit hole

90° Stanchion

417x300x201mm (30-100W)
457x380x217mm (120-240W)
1 conduit hole

Trunnion Mount

300x348mm (30-100W)
380x365mm (120-240W)
4 conduit holes

Hazardous Area Industries

Oil and Gas

Refineries, LNG terminals, petrochemical plants, and offshore platforms where Zone 2 explosive gas atmospheres are present. Marine certification covers coastal and offshore installations.

Chemical Processing

Chemical manufacturing facilities, solvent storage areas, and processing plants requiring certified lighting for volatile atmosphere environments with C4 corrosion resistance.

Mining Operations

Surface processing, mineral handling, conveyor corridors, and underground operations where explosive dust atmospheres (Zone 21/22) demand certified luminaires with heavy duty construction.

Marine and Coastal

Port facilities, shipyards, and coastal infrastructure where salt spray and corrosive conditions require UL1598A Marine certified fixtures with marine grade aluminium construction.

Grain and Agriculture

Grain silos, flour mills, feed processing, and agricultural storage facilities where combustible dust creates Zone 21/22 hazardous areas requiring certified illumination.

Power Generation

Power stations, transformer yards, and generating facilities where hazardous area classifications require certified lighting capable of operating across extreme temperature ranges.

AU-HA05 explosion-proof highbay certified for Australian hazardous areas

Certified for Australian Hazardous Areas

The AU-HA05 meets IECEx and ATEX certification requirements for installation in hazardous areas as defined by AS/NZS 60079. Zone 2 gas environments and Zone 20, 21, and 22 dust environments are covered by the Ex nR IIC T6/T5 Gc and Ex tb IIIC T80°C/T95°C Db IP66 classifications. North American NEC and CEC certifications cover Class I Division 2 and Class II Division 1 and 2 installations.

As required by Australian regulations, this luminaire must be installed and maintained by licensed professionals in accordance with local codes and site specific hazardous area classifications. Eye Lighting Australia provides full technical support and documentation for compliance requirements.

Frequently Asked Questions

What hazardous zones is the AU-HA05 certified for?

The AU-HA05 is certified for Zone 2, Zone 20, Zone 21, and Zone 22 hazardous areas, plus Class I Division 2 (C1D2) under NEC and CEC standards. It carries IECEx, ATEX, and UL1598A Marine certifications, making it suitable for gas, dust, and marine environments.

What power options are available for the AU-HA05?

Nine power configurations from 30W (4,200 lumens) to 240W (33,600 lumens). All models achieve up to 140 lm/W efficacy at 4000K Ra70. The full range can replace HPS fixtures up to 700W, significantly reducing energy consumption and eliminating re-strike delays.

What mounting options does the AU-HA05 offer?

Six configurations from one certified platform: ceiling, pendant, wall bracket, trunnion, 25 degree stanchion, and 90 degree stanchion. One product family, one certification chain, one set of spares for every hazardous area on site.

Does the AU-HA05 have an emergency lighting option?

Yes. The AU-HA05-050 (50W) includes built in emergency backup providing 1,620 lumens for 90 minutes or 720 lumens for 3 hours during power loss, ensuring personnel safety in hazardous environments.

What dimming options are available?

The AU-HA05 supports 1-10V analogue dimming, DALI digital dimming, and a non-dimmable configuration. This provides integration flexibility for building management systems and lighting control strategies.

What corrosion protection does the AU-HA05 provide?

Marine grade copper-free aluminium alloy housing with C4 corrosion resistance. Stainless steel hardware and brackets with anti-corrosion treatment. UL1598A Marine certified for coastal, offshore, and high-corrosion environments. Operates from minus 40°C to plus 65°C.

50+ Years of Industrial Lighting Expertise

Eye Lighting Australia has supplied specialised industrial lighting solutions across Australia and New Zealand for over 50 years. Our hazardous area lighting range meets the strict certification requirements of Australian mining, oil and gas, chemical processing, and marine industries.

From product selection through to installation support and ongoing technical assistance, our team understands the compliance requirements and practical challenges of lighting hazardous environments. Contact us for expert advice on zone classification and luminaire selection for your facility.

AU-HA05 LED Explosion-Proof Highbay ceiling mount

Need Explosion-Proof Lighting for Your Facility?

Contact Eye Lighting Australia for expert advice on the AU-HA05 and hazardous area lighting solutions for Zone 2, Zone 21, Zone 22, and C1D2 environments.

Request a Quote

Tel: 1800 635 383 | Email: info@eli.com.au