AU-HA06 LED Explosion-Proof Linear Light
Zone 2 and C1D2 Hazardous Areas
AU-HA06 explosion-proof LED linear lighting delivers certified performance for Zone 2, Zone 21, Zone 22, and Class I Division 2 hazardous environments. With a fibre-reinforced plastic housing that eliminates galvanic corrosion, 160 lm/W efficacy, and eight power options from 20W to 100W producing up to 16,000 lumens, the AU-HA06 provides walkway, corridor, and area lighting across oil refineries, chemical plants, mining operations, and marine installations in 2FT and 4FT configurations.
Linear Lighting Built for Hazardous Environments
Fibre-Reinforced Plastic Housing
No galvanic corrosion. No rusting. The composite body outperforms metal housings in marine and chemical environments where salt spray and acidic atmospheres accelerate the failure of aluminium and steel fixtures.
160 lm/W Efficacy
Industry leading efficiency at 5000K Ra70. Eight power configurations from 20W to 100W replace fluorescent tube fixtures, eliminating re-lamping cycles and reducing energy consumption across the entire installation.
14 Optic Lens Options
Fourteen lens configurations plus clear or diffused covers enable precise light distribution for every application. Narrow beams for corridors, wide floods for processing areas, and asymmetric patterns for wall wash effects.
Emergency Backup Options
Built in emergency lighting maintains illumination during power loss. Three configurations are available: 10W for 3 hours, 20W for 90 minutes, or 9W for 90 minutes, ensuring safe evacuation in hazardous environments.
Two Sizes, One Certification Chain
Hazardous area corridor lighting rarely involves a single fixture length. A processing plant might need compact 2FT units in confined spaces and full 4FT fixtures along extended walkways. Specifying different product families for each length means separate certification documents, separate spare parts, and separate compliance records.
The AU-HA06 eliminates that problem. Both the 618mm (2FT) and 1232mm (4FT) body sizes share the same certification chain, the same mounting hardware, and the same driver platform. Loop-in and loop-out terminal blocks with three conduit holes simplify wiring across multi-fixture runs, cutting both material and labour costs on walkway and corridor installations.
AU-HA06 Model Variants
AU-HA06-020
The compact 20W model delivers 3,200 lumens for confined spaces and secondary corridors in hazardous areas where lower output is sufficient and space is limited.
- Power 20W
- Luminous Flux 3,200 lm
- Body Size 2FT (618mm)
AU-HA06-060
Mid-range output for primary corridors, walkways, and processing areas requiring certified linear illumination with broad coverage and efficient energy use.
- Power 60W
- Luminous Flux 9,600 lm
- Efficacy 160 lm/W
AU-HA06-100
Maximum output for large processing areas and extended corridor runs. The 100W model in 4FT configuration replaces multiple fluorescent fittings with a single certified fixture.
- Power 100W
- Luminous Flux 16,000 lm
- Body Size 4FT (1232mm)
AU-HA06 Technical Data
| Power Options | 20W / 30W / 40W / 50W / 60W / 70W / 80W / 100W (±5%) |
|---|---|
| Input Voltage | 24-48Vac / 120-277Vac / 277-480Vac (no 20W), 50/60Hz; 18-48Vdc |
| Luminous Flux | 3,200 lm (20W) to 16,000 lm (100W) ±10% |
| Efficacy | Up to 160 lm/W (5000K Ra70) |
| Body Sizes | 2FT (618mm) and 4FT (1232mm) |
| Colour Temperature | 5000K standard (2000K, 2200K, 2500K, 2700K, 3000K, 3500K, 4000K, 4500K, 5700K, 6500K optional) |
| CRI | Ra70 / Ra80 / Ra90 |
| Coloured LED Options | Red, Green, Blue, Amber |
| Beam Angles | 14 optic lens options plus clear or diffused cover |
| Dimming | 1-10V or Non-dimmable |
| IP Rating | IP66 |
| Impact Resistance | IK08 |
| Operating Temperature | -40°C to +55°C (model dependent) |
| Housing Material | Fibre-Reinforced Plastic (marine grade corrosion resistance) |
| Emergency Options | 10W for 3 hours, 20W for 90 minutes, or 9W for 90 minutes |
| Cable Entry | M25×1.5, M20×1.5, M32×1.5, 3/4" NPT, 1/2" NPT, 1" NPT |
| IECEx Certification | Ex nR IIC T6 Gc / Ex tb IIIC T80°C Db |
| ATEX Certification | II 3G Ex nR IIC T6 Gc / II 2D Ex tb IIIC T80°C Db |
| NEC/CEC | Class I Div 2 (A,B,C,D) / Class II Div 2 (F,G) / Class III / UL1598A Marine |
| Warranty | 5 Years |
Six Mounting Configurations
Ceiling Mount
618x150x202mm (2FT)
1232x150x202mm (4FT)
3.4 kg / 5.0 kg
Pendant Mount
618x120x178mm (2FT)
1232x120x178mm (4FT)
3.3 kg / 4.9 kg
Trunnion Mount
618x120x202mm (2FT)
1232x120x202mm (4FT)
3.5 kg / 5.1 kg
Hoop Mount
618x125x225mm (2FT)
1232x125x225mm (4FT)
3.5 kg / 5.1 kg
Loop Mount
618x125x218mm (2FT)
1232x125x218mm (4FT)
3.4 kg / 5.0 kg
Recessed Mount
618x170x114mm (2FT)
1232x170x114mm (4FT)
3.4 kg / 5.0 kg
Hazardous Area Industries
Oil and Gas
Walkways, corridors, pipe racks, and access routes across refineries, LNG terminals, and petrochemical plants where Zone 2 explosive gas atmospheres require certified linear lighting for safe personnel movement.
Chemical Processing
Chemical manufacturing corridors, solvent storage areas, and laboratory access ways requiring certified lighting. The fibre-reinforced plastic housing provides superior resistance to acidic and alkaline atmospheres.
Mining Operations
Conveyor tunnels, underground access corridors, and processing walkways where Zone 21/22 explosive dust atmospheres demand certified linear fixtures with robust construction and emergency backup capability.
Marine and Coastal
Port facilities, shipyards, and offshore platform corridors where salt spray and marine atmospheres cause rapid degradation of metal fixtures. The composite housing eliminates galvanic corrosion entirely.
Food and Beverage
Processing corridors and production areas where combustible dust and regular washdown environments require IP66 rated fixtures. Available in Ra90 CRI for accurate colour rendering where visual inspection is required.
Power Generation
Turbine halls, transformer corridors, and generating facility access routes where hazardous area classifications require certified lighting capable of operating across the full -40°C to +55°C temperature range.
Certified for Australian Hazardous Areas
The AU-HA06 meets IECEx and ATEX certification requirements for installation in hazardous areas as defined by AS/NZS 60079. Zone 2 gas environments and Zone 21 and 22 dust environments are covered by the Ex nR IIC T6 Gc and Ex tb IIIC T80°C Db classifications. North American NEC and CEC certifications cover Class I Division 2 and Class II Division 2 installations.
The DC input voltage option (18-48Vdc) supports battery backed systems and mining vehicles where AC power is unavailable. As required by Australian regulations, this luminaire must be installed and maintained by licensed professionals in accordance with local codes and site specific hazardous area classifications. Eye Lighting Australia provides full technical support and documentation for compliance requirements.
Frequently Asked Questions
What hazardous zones is the AU-HA06 certified for?
The AU-HA06 is certified for Zone 2 gas environments, Zone 21 and 22 dust environments, and Class I Division 2 under NEC and CEC standards. It carries IECEx, ATEX, UL844, and UL1598A Marine certifications, making it suitable for gas, dust, and marine environments.
What sizes are available for the AU-HA06?
Two body lengths: 2FT (618mm) for compact installations and 4FT (1232mm) for extended coverage. Both sizes support all six mounting configurations and all power options, sharing the same certification chain and spare parts.
What power options does the AU-HA06 offer?
Eight power configurations from 20W (3,200 lumens) to 100W (16,000 lumens). All models achieve up to 160 lm/W efficacy at 5000K Ra70, providing significant energy savings over fluorescent tube replacements in hazardous area installations.
Why does the AU-HA06 use fibre-reinforced plastic?
The fibre-reinforced plastic housing provides superior corrosion resistance compared to metal alternatives, particularly in marine and chemical environments. It eliminates galvanic corrosion entirely, provides lighter weight for easier installation, and maintains structural integrity in acidic and alkaline atmospheres.
Does the AU-HA06 have emergency lighting options?
Yes. Three emergency backup configurations are available: 10W output for 3 hours, 20W output for 90 minutes, and 9W output for 90 minutes. This ensures maintained illumination for personnel safety during power loss in hazardous environments.
How many optic lens options are available?
Fourteen different optic lens configurations for precise light distribution, plus clear or diffused cover options. This allows optimised illumination for walkways, corridors, processing areas, and open floor spaces where different beam patterns are required for compliance and safety.
50+ Years of Industrial Lighting Expertise
Eye Lighting Australia has supplied specialised industrial lighting solutions across Australia and New Zealand for over 50 years. Our hazardous area lighting range meets the strict certification requirements of Australian mining, oil and gas, chemical processing, and marine industries.
From product selection through to installation support and ongoing technical assistance, our team understands the compliance requirements and practical challenges of lighting hazardous environments. Contact us for expert advice on zone classification and luminaire selection for your facility.
Need Explosion-Proof Linear Lighting?
Contact Eye Lighting Australia for expert advice on the AU-HA06 and hazardous area linear lighting solutions for Zone 2, Zone 21, Zone 22, and C1D2 environments.
Request a QuoteTel: 1800 635 383 | Email: info@eli.com.au