IP66 • 20W / 32W LED • 4000K

Bulkheads Lighting for Mining in Australia:
Prismalux / Solarlux

Prismalux and Solarlux are heavy duty bulkhead luminaires designed for extremely dirty and moist conditions. The range uses a die-cast LM6M aluminium body, an internally prismatic borosilicate glass lens, symmetrical wide beam distribution and IP66 protection, with ceiling, wall and pole mounting options.

View Prismalux / Solarlux
Prismalux heavy duty IP66 bulkhead luminaire with protective wire guard
IP66
Ingress Protection
20W / 32W
Prismalux LED
2,535 / 3,440 lm
LED Output
4000K
LED Colour Temperature
>60,000 h
LED Life L70 / B10

Bulkhead construction for dirty and moist areas

Made for dirty and moist conditions

Heavy duty bulkhead construction suits operating areas exposed to persistent dirt and moisture.

Prismatic glass lens

Its 9mm borosilicate lens has an internal prismatic surface and a nylon coated steel wire guard.

Serviceable construction

Hinged lens-frame access reaches the lamp and control gear, while the gear assembly can be removed for workshop servicing.

Documented EMC compliance

Product information states compliance with the provisions of AS/NZS CISPR 15:2011.

Bulkhead lighting for mining access routes

Wide symmetrical light distribution supports tunnels, walkways, footpaths, subways, stairways and security areas. Current product information also places the range in mining categories that include CHPP, industrial workshops, mineral sands facilities and preparation plants.

Eye Lighting's current Ready4Mining guide includes LED models at 20W and 32W, with 4000K light and IP66 ingress protection.

Fixed plant mining walkway and stairwell lighting application context
Dirty and moist mining service bay lighting application context

Construction for demanding service areas

Pre-treated and black powder coated LM6M die-cast aluminium forms the housing. A white powder coated aluminium reflector sits behind the 9mm glass lens and its internal prismatic surface.

In ambient temperatures up to 40°C, the aluminium body is designed to dissipate heat. Stainless steel helicoils separate stainless steel threads from the body, while the smooth external surface helps limit dirt and debris build-up.

Mounting, wiring and maintenance access

Ceiling mounting is the brochure's primary arrangement, with wall and pole options also published. Four mounting positions sit outside the gasket area, and two M20 x 1.5 threaded entries support incoming cable and looping requirements.

Installation requires cable glands rated to at least IP66. Before the lens assembly is secured, gasket and joining surfaces must be clean and enclosure screws tightened evenly in a diagonally opposed pattern. Switch off and isolate mains power before servicing.

Transparent Prismalux bulkhead product view showing the lens and wire guard

Published LED and discharge lamp configurations

Prismalux LED 20W

4000K • Symmetrical Wide Beam

The 20W Prismalux LED configuration provides 2,535 lumens with an integral driver and the published IP66 bulkhead construction.

  • Product Code 186310
  • Power 20W LED
  • Output 2,535 lm
  • CCT 4000K

View Prismalux / Solarlux

Prismalux LED 32W

4000K • Symmetrical Wide Beam

Its 32W LED configuration provides 3,440 lumens with an integral driver and the same heavy duty IP66 housing.

  • Product Code 186315
  • Power 32W LED
  • Output 3,440 lm
  • CCT 4000K

View Prismalux / Solarlux

HID Lamp Range

CMH • Mercury Vapour • HPS

Published Prismalux and Solarlux options include ceramic metal halide, mercury vapour and high pressure sodium configurations.

  • Prismalux CMH 70W / 115W
  • Prismalux MV 80W / 125W
  • Solarlux HPS 70W / 110W
  • Distribution Symmetrical wide beam

View Prismalux / Solarlux

Technical data

Product Prismalux / Solarlux
Operating Environment Extremely dirty and moist conditions
Ingress Protection IP66
Electrical Class Class I
Body LM6M die-cast aluminium
Body Finish Pre-treated and black powder coated
Lens Internally prismatic borosilicate glass
Lens Thickness 9mm
Reflector White powder coated aluminium
Beam Symmetrical wide beam
Control Gear / Driver Integral
Terminal Block Fused
Mounting Ceiling, wall or pole
Conduit Entries Two M20 x 1.5 threaded entries
Maintenance Access Hinged lens frame assembly
Control Gear Servicing Removable assembly for workshop servicing
Lens Protection Nylon coated steel wire guard
Ambient Condition Aluminium body dissipates heat at 40°C ambient
Thread Interface Stainless steel helicoils
EMC AS/NZS CISPR 15:2011
Prismalux LED Power 20W or 32W
Prismalux LED Output 2,535 lm or 3,440 lm
LED CCT 4000K
LED CRI Ra 70
LED Life >60,000 hours L70 / B10
Driver Efficiency >85%
Power Factor >0.95
LED Efficacy 81.5 lm/W
Main Body Drawing 320mm x 210mm, depth 175mm
Mounting Centres 290mm x 150mm

Ceiling, wall and pole mounting details

Ceiling Mount

Brochure information identifies ceiling mounting as the primary arrangement.

Wall Mount

Wall or Unistrut fixing uses the published surface mount bracket.

Pole Mount

Pole brackets support 50mm outside diameter U-bolt fixing or slip fit mounting for 32mm and 50mm outside diameter pipe.

Gasket Protection

Four mounting positions are located outside the gasket area to preserve the enclosure seal.

Cable and Looping

Two M20 x 1.5 threaded entries are available for incoming cables and through wiring. Use cable glands with an IP66 rating or higher.

Isolated Maintenance

Disconnect and isolate the mains supply before servicing, then clean the gasket surfaces before reassembly.

Where Prismalux and Solarlux are designed to operate

Tunnels

Heavy duty bulkhead lighting for tunnel access routes.

Walkways

Symmetrical wide beam lighting for industrial and mining walkways.

Footpaths

Published applications include exterior and industrial footpaths.

Subways

Prismalux and Solarlux are listed for subway and underpass routes.

Stairways

Bulkhead lighting for stairways in dirty or moist operating areas.

Security Areas

Security area illumination appears in the published application list.

CHPP

Current product information places Prismalux / Solarlux in the CHPP application category.

Industrial Workshops

Industrial workshop applications appear in the current product record.

Preparation Plants

Preparation plant areas are included in the current product categories.

Prismalux and Solarlux bulkhead questions

What are Prismalux and Solarlux designed for?

Built as heavy duty bulkhead luminaires, Prismalux and Solarlux suit areas affected by dirt and moisture. Published applications include tunnels, walkways, footpaths, subways, stairways and security areas.

What Prismalux LED outputs are published?

Output is 2,535 lumens at 20W and 3,440 lumens at 32W. Both configurations use a symmetrical wide beam.

What are the Prismalux LED colour and life figures?

For both LED configurations, the brochure records 4000K, Ra 70 and more than 60,000 hours to L70 / B10.

What protection rating is documented?

Class I and IP66 ratings are documented for the Prismalux / Solarlux range. Installation requires IP66 or higher cable glands.

What materials are used?

An LM6M die-cast aluminium housing carries a black powder coating. Its 9mm borosilicate glass lens has an internal prismatic surface and a nylon coated steel wire guard.

How can Prismalux / Solarlux be mounted?

Mounting options include ceiling, wall and pole arrangements. Four mounting holes sit outside the gasket line.

What wiring provisions are provided?

A pair of M20 x 1.5 threaded cable entries supports incoming cables and looping. Installation instructions require correctly tightened glands with an IP66 rating or higher, plus clean gasket surfaces.

What maintenance precautions apply?

Fully isolate the mains supply before servicing. Exterior build-up can be cleaned with water and mild detergent, and a broken glass lens must be replaced immediately.

Prismalux LED in the Ready4Mining range

Eye Lighting's current Ready4Mining guide includes Prismalux LED as a heavy duty bulkhead for areas exposed to dirt and moisture. It records 20W and 32W LED configurations, 4000K light and IP66 protection.

Product selection should be confirmed against current Prismalux / Solarlux product information, installation instructions and the requirements of the proposed site.

Eye Lighting Prismalux bulkhead application artwork for a moist industrial environment

Need bulkhead lighting for a mining or industrial project?

Contact Eye Lighting Australia for current Prismalux / Solarlux product information and application engineering support.

Contact Eye Lighting Australia

Tel: 1800 635 383 | Email: info@eli.com.au