Bulkheads Lighting for Mining in Australia:
Prismalux / Solarlux
Prismalux and Solarlux are heavy duty bulkhead luminaires designed for extremely dirty and moist conditions. The range uses a die-cast LM6M aluminium body, an internally prismatic borosilicate glass lens, symmetrical wide beam distribution and IP66 protection, with ceiling, wall and pole mounting options.
View Prismalux / Solarlux
Bulkhead construction for dirty and moist areas
Made for dirty and moist conditions
Heavy duty bulkhead construction suits operating areas exposed to persistent dirt and moisture.
Prismatic glass lens
Its 9mm borosilicate lens has an internal prismatic surface and a nylon coated steel wire guard.
Serviceable construction
Hinged lens-frame access reaches the lamp and control gear, while the gear assembly can be removed for workshop servicing.
Documented EMC compliance
Product information states compliance with the provisions of AS/NZS CISPR 15:2011.
Bulkhead lighting for mining access routes
Wide symmetrical light distribution supports tunnels, walkways, footpaths, subways, stairways and security areas. Current product information also places the range in mining categories that include CHPP, industrial workshops, mineral sands facilities and preparation plants.
Eye Lighting's current Ready4Mining guide includes LED models at 20W and 32W, with 4000K light and IP66 ingress protection.
Construction for demanding service areas
Pre-treated and black powder coated LM6M die-cast aluminium forms the housing. A white powder coated aluminium reflector sits behind the 9mm glass lens and its internal prismatic surface.
In ambient temperatures up to 40°C, the aluminium body is designed to dissipate heat. Stainless steel helicoils separate stainless steel threads from the body, while the smooth external surface helps limit dirt and debris build-up.
Mounting, wiring and maintenance access
Ceiling mounting is the brochure's primary arrangement, with wall and pole options also published. Four mounting positions sit outside the gasket area, and two M20 x 1.5 threaded entries support incoming cable and looping requirements.
Installation requires cable glands rated to at least IP66. Before the lens assembly is secured, gasket and joining surfaces must be clean and enclosure screws tightened evenly in a diagonally opposed pattern. Switch off and isolate mains power before servicing.
Published LED and discharge lamp configurations
Prismalux LED 20W
4000K • Symmetrical Wide Beam
The 20W Prismalux LED configuration provides 2,535 lumens with an integral driver and the published IP66 bulkhead construction.
- Product Code 186310
- Power 20W LED
- Output 2,535 lm
- CCT 4000K
Prismalux LED 32W
4000K • Symmetrical Wide Beam
Its 32W LED configuration provides 3,440 lumens with an integral driver and the same heavy duty IP66 housing.
- Product Code 186315
- Power 32W LED
- Output 3,440 lm
- CCT 4000K
HID Lamp Range
CMH • Mercury Vapour • HPS
Published Prismalux and Solarlux options include ceramic metal halide, mercury vapour and high pressure sodium configurations.
- Prismalux CMH 70W / 115W
- Prismalux MV 80W / 125W
- Solarlux HPS 70W / 110W
- Distribution Symmetrical wide beam
Technical data
| Product | Prismalux / Solarlux |
|---|---|
| Operating Environment | Extremely dirty and moist conditions |
| Ingress Protection | IP66 |
| Electrical Class | Class I |
| Body | LM6M die-cast aluminium |
| Body Finish | Pre-treated and black powder coated |
| Lens | Internally prismatic borosilicate glass |
| Lens Thickness | 9mm |
| Reflector | White powder coated aluminium |
| Beam | Symmetrical wide beam |
| Control Gear / Driver | Integral |
| Terminal Block | Fused |
| Mounting | Ceiling, wall or pole |
| Conduit Entries | Two M20 x 1.5 threaded entries |
| Maintenance Access | Hinged lens frame assembly |
| Control Gear Servicing | Removable assembly for workshop servicing |
| Lens Protection | Nylon coated steel wire guard |
| Ambient Condition | Aluminium body dissipates heat at 40°C ambient |
| Thread Interface | Stainless steel helicoils |
| EMC | AS/NZS CISPR 15:2011 |
| Prismalux LED Power | 20W or 32W |
| Prismalux LED Output | 2,535 lm or 3,440 lm |
| LED CCT | 4000K |
| LED CRI | Ra 70 |
| LED Life | >60,000 hours L70 / B10 |
| Driver Efficiency | >85% |
| Power Factor | >0.95 |
| LED Efficacy | 81.5 lm/W |
| Main Body Drawing | 320mm x 210mm, depth 175mm |
| Mounting Centres | 290mm x 150mm |
Ceiling, wall and pole mounting details
Ceiling Mount
Brochure information identifies ceiling mounting as the primary arrangement.
Wall Mount
Wall or Unistrut fixing uses the published surface mount bracket.
Pole Mount
Pole brackets support 50mm outside diameter U-bolt fixing or slip fit mounting for 32mm and 50mm outside diameter pipe.
Gasket Protection
Four mounting positions are located outside the gasket area to preserve the enclosure seal.
Cable and Looping
Two M20 x 1.5 threaded entries are available for incoming cables and through wiring. Use cable glands with an IP66 rating or higher.
Isolated Maintenance
Disconnect and isolate the mains supply before servicing, then clean the gasket surfaces before reassembly.
Where Prismalux and Solarlux are designed to operate
Tunnels
Heavy duty bulkhead lighting for tunnel access routes.
Walkways
Symmetrical wide beam lighting for industrial and mining walkways.
Footpaths
Published applications include exterior and industrial footpaths.
Subways
Prismalux and Solarlux are listed for subway and underpass routes.
Stairways
Bulkhead lighting for stairways in dirty or moist operating areas.
Security Areas
Security area illumination appears in the published application list.
CHPP
Current product information places Prismalux / Solarlux in the CHPP application category.
Industrial Workshops
Industrial workshop applications appear in the current product record.
Preparation Plants
Preparation plant areas are included in the current product categories.
Prismalux and Solarlux bulkhead questions
What are Prismalux and Solarlux designed for?
Built as heavy duty bulkhead luminaires, Prismalux and Solarlux suit areas affected by dirt and moisture. Published applications include tunnels, walkways, footpaths, subways, stairways and security areas.
What Prismalux LED outputs are published?
Output is 2,535 lumens at 20W and 3,440 lumens at 32W. Both configurations use a symmetrical wide beam.
What are the Prismalux LED colour and life figures?
For both LED configurations, the brochure records 4000K, Ra 70 and more than 60,000 hours to L70 / B10.
What protection rating is documented?
Class I and IP66 ratings are documented for the Prismalux / Solarlux range. Installation requires IP66 or higher cable glands.
What materials are used?
An LM6M die-cast aluminium housing carries a black powder coating. Its 9mm borosilicate glass lens has an internal prismatic surface and a nylon coated steel wire guard.
How can Prismalux / Solarlux be mounted?
Mounting options include ceiling, wall and pole arrangements. Four mounting holes sit outside the gasket line.
What wiring provisions are provided?
A pair of M20 x 1.5 threaded cable entries supports incoming cables and looping. Installation instructions require correctly tightened glands with an IP66 rating or higher, plus clean gasket surfaces.
What maintenance precautions apply?
Fully isolate the mains supply before servicing. Exterior build-up can be cleaned with water and mild detergent, and a broken glass lens must be replaced immediately.
Prismalux LED in the Ready4Mining range
Eye Lighting's current Ready4Mining guide includes Prismalux LED as a heavy duty bulkhead for areas exposed to dirt and moisture. It records 20W and 32W LED configurations, 4000K light and IP66 protection.
Product selection should be confirmed against current Prismalux / Solarlux product information, installation instructions and the requirements of the proposed site.
Need bulkhead lighting for a mining or industrial project?
Contact Eye Lighting Australia for current Prismalux / Solarlux product information and application engineering support.
Contact Eye Lighting AustraliaTel: 1800 635 383 | Email: info@eli.com.au