CHPP & Fixed Plant Lighting

A coal handling plant is not one environment. Your lighting should not be one fitting.

A coal handling plant runs through conveyors, transfer towers, crushers, screens, reclaim tunnels, stockpiles, load out, plant rooms and workshops. Each of these areas places different demands on a luminaire, and each one fails in a different way when the specification is wrong.

Built for heavy industry IP66 ingress IK08鈥揑K09 impact AS/NZS 60598 3G vibration tested Marine grade LM6 alloy Remote driver to 60m Surge to 25kA IECEx hazardous options
The approach

More light alone does not solve a lighting problem.

Coal handling and preparation plants (CHPPs) create visibility problems you rarely meet in a standard industrial shed. Dust settles on lenses and steadily reduces the light that reaches the floor, washdown and process water work away at seals, and structural steel breaks beams into shadow. People work around belts, chutes, idlers, screens, stairs, hatches and isolation points, and they need to keep moving safely when a section is isolated or the power drops.

A brightly lit plant can still be unsafe to work in.

The wrong beam angle, mounting height, fixture body, driver location or emergency choice can leave a plant flooded with light yet still hard to inspect, hard to move through during an outage, and costly to run. The first question is not which fitting to buy. It is how to classify the lighting problem in each area.

01

Dust & contamination

Coal dust cuts delivered light, flattens contrast and hides trip points. Lens design, mounting angle, serviceability and cleaning intervals matter as much as the lumen package on the specification sheet.

02

Glare & shadow

Low mounting along walkways sends light straight into the eye, while transfer points cast heavy shadow under chutes and platforms. Uniformity and beam control are the factors most often overlooked.

03

Outage consequence

Galleries, reclaim tunnels and stair towers need egress designed in from the start. Emergency fittings belong on the plant layout early, not added once the project is nearly finished.

The environment

Understand the plant before you specify a product.

Conveyors, transfer structures, process buildings, bins, galleries and access ways all decide where light can reach and where it is blocked. Specification should start there.

In-plant conveyors and transfer towers at a coal handling facility
In-plant conveyors, transfer towers and fixed plant steel
Conveyor running into a raised raw coal bin structure
Conveyor into bin and raised structure
Process plant, walkways and transfer areas at a coal preparation plant
Process plant, walkways and transfer areas
Operating conditions

The same layout can face very different conditions.

Two plants can share the same layout and still need different lighting solutions. A high dust inland site, a high rainfall region, a hot enclosed plant and a coastal terminal each call for a different specification. Dust load, wet season, ambient heat, vibration, salt air and how easily a fitting can be reached all shape the final choice.

Coal dustBuild up affects output, contrast and cleaning intervals, and can trigger a hazardous area assessment under AS/NZS 60079.10.2 depending on the site.
WashdownHoses, wet floors, process water and rain put ingress protection and gasket reliability front and centre.
HeatAmbient temperature, enclosed plant and driver location all shape service life and thermal performance.
Salt airCoastal terminals and ship loaders need corrosion resistant housings, coatings and fixings such as 316 stainless.
VibrationCrushers, screens and conveyors fatigue weak brackets, cable entries and internal parts over time.
Zone by zone

Break the plant into lighting zones first.

Each zone has its own challenge, its own operating conditions and its own place in the Eye range. The sections below work through them in order.

Zone 01

Conveyor galleries, gantries and access walkways

Conveyor runs are long and repetitive, which makes them easy to underestimate. The lighting has to support walking, belt tracking, idler checks, pull wire access and stair transitions, and it must keep working as an escape route during an outage. A single bright fitting every few metres leaves dark gaps and harsh glare in between.

  • Aim for continuous route visibility and even coverage.
  • Control glare where fittings sit near eye level.
  • Plan emergency lighting where the route doubles as egress.

In the range: ConV1, ConV2 and ConV2 Emergency pole mounted conveyor luminaires, with L-Line / TB and L-Line Emergency / TB sealed linears.

Interior coal conveyor gallery with walkway lighting
Coal handling plant transfer station and process structures
Zone 02

Transfer stations, chutes and clean up areas

Transfer stations are where lighting most often falls short. Chutes, skirts, guarding, pipework and structural steel all block light. Spillage and dust call for good clean up visibility, and inspection hatches and isolation points need clear task light in the very places the steel gets in the way.

  • Layer linear route lighting with local flood or task light.
  • Place light around the steel instead of asking one flood to cover the whole structure.
  • Account for washdown, dust build up and impact.

In the range: L-Line / TB linears, Turbo and Turbo.Mini floodlights, KL-Series floodlights.

Zone 03

Crushers, screens and vibrating fixed plant

Crushers and screens put fittings under constant vibration, and this is where general industrial lighting fails early. The fitting needs strong brackets, a sound driver strategy and lenses that stay effective through dust and heat. Turbo delivers up to 90,000 lumens at 150 lm/W from a 600W head, is vibration tested to IEC 60068-2-6 (3G across all three axes, five hours per axis), and carries 25kA surge protection with the driver mountable up to 60 metres from the machine.

  • Use vibration aware products and mounting detail.
  • Keep general area light separate from inspection and task light.
  • Allow for acoustic enclosures, steel shadow and heavy dust.

In the range: Turbo, KL-Series, Ultra, Netsu high temperature high bay, and BOYLE Xtrem for hazardous duty.

Coal crusher house and conveyor gallery requiring vibration rated lighting
Coal handling plant silo and enclosed conveyor structure
Zone 04

Reclaim tunnels, enclosed routes and emergency paths

Reclaim tunnels and enclosed conveyor routes need more than everyday operating light. The cost of losing power is far higher below ground. Egress, runtime, maintained or non maintained strategy, water ingress and area classification all need to be settled before any fitting is installed, with emergency escape lighting designed to AS/NZS 2293.

  • Map emergency coverage as a continuous route, not as isolated fittings.
  • Confirm hazardous area classification to AS/NZS 60079 before selecting equipment.
  • Use sealed linear lighting where access for maintenance is tight.

In the range: SST Emergency and Emlux LED Emergency bulkheads, L-Line Emergency / TB and ConV2 Emergency.

Planning lighting for a CHPP or fixed plant?

Send us your zones and operating conditions, and you will receive a shortlist matched to the plant, not a catalogue to work through.

The range

The Eye range, grouped by what it does on the plant.

The range is grouped by the job each family does in a particular part of the plant, so a contractor lighting a reclaim tunnel and an engineer specifying a crusher house can both find the right starting point quickly.

Conveyors & access

ConV1 / ConV2 / ConV2 Emergency

Pole mounted LED luminaires, IP66 and IK08, with asymmetrical optics for long conveyor runs and walkways. ConV1 reaches up to 100 lm/W in an LM6 housing with tool free servicing, ConV2 is the 80W option, and ConV2 Emergency adds an integral battery for routes that double as egress.

Conveyors 路 gantries 路 raised walkways
Sealed linears

L-Line / TB & L-Line Emergency / TB

Surface mount LED linears in corrosion resistant materials, with a terminal box for easy connection and emergency variants. Suited to plant rooms, tunnels, walkways, platforms and wet routes.

Linear access 路 tunnels 路 workshops
Floodlighting

Turbo / Turbo.Mini

Turbo delivers up to 90,000 lumens at 150 lm/W (600W), IP66 and IK08, 3G vibration tested to IEC 60068-2-6 with 25kA surge protection and a remote driver up to 60m. Turbo.Mini is the compact IP66 / IK09 version in LM6 aluminium with a tempered glass lens and 316 stainless hardware, for tight structures, lower mounting and tunnels.

Floodlighting 路 hardstand 路 process structures
High output & harsh duty

KL-Series / BOYLE Xtrem / Ultra / Netsu

KL-Series floodlights (IP66 / IK09, surge to 10kA, symmetrical or asymmetrical optics, smart controls on request) for large areas. BOYLE Xtrem is IECEx and ATEX certified for Zone 2, 21 and 22 (IP66 / IP68 / IP69K, 70,000 h L80, CRI > 80) for hazardous dust and gas atmospheres. Netsu is a high bay rated for ambients up to 70°C, IP66 with IK09 glass or IK10 composite lens.

Harsh plant 路 high output 路 process areas
Emergency & egress

SST Emergency / Emlux LED Emergency

Integral battery LED bulkheads for adverse industrial and mining duty. SST Emergency is a high powered multi use bulkhead, and Emlux LED Emergency is thermally tested for a 15 to 20 year service life at up to 50°C ambient. Used across tunnels, stairs, switchrooms, plant rooms and any outage critical movement path.

Emergency 路 egress 路 outage planning
General & supporting

Cirro Cumulus / Prismalux / Solarlux / Hera

Cirro Cumulus is a 450W LED high bay and floodlight for everyday industrial areas, Prismalux and Solarlux are heavy duty bulkheads for dirty and wet conditions, and Hera covers amenity lighting for the rooms and walkways around the core plant.

High bay 路 heavy duty bulkheads 路 amenities
Application matrix

Find your area, find your shortlist.

This matrix is deliberately detailed. Match the area you are lighting to the problem, the operating risk and the product families worth discussing.

Area Lighting problem Environment risk Design angle Eye range to discuss
Conveyor gallery Dark gaps between fittings, glare on narrow walkways, poor visibility at idlers, pull wires and stairs. Dust, vibration, long runs, low mounting height, limited shutdown access. Even route lighting, low glare, maintainable fittings, emergency continuity where the route is used for egress. ConV1, ConV2, ConV2 Emergency, L-Line / TB, L-Line Emergency / TB.
Transfer station Shadow under chutes and platforms, poor clean up visibility, obstruction from steel, pipework and guarding. Dust clouds, impact risk, washdown, spillage, awkward mounting surfaces. Layered light: route lighting plus local flood or task light for inspection, clean up and isolation points. L-Line / TB, Turbo, Turbo.Mini, KL-Series.
Crusher house / screen house Fittings failing from vibration, maintenance faces left dark, high output light creating glare if uncontrolled. Vibration, dust, heat, acoustic enclosures, raised platforms. Strong body and brackets, thermal management, separated task and general lighting. Turbo, KL-Series, Ultra, Netsu, BOYLE Xtrem.
Reclaim tunnel Unsafe movement in an outage, dirty lenses, hard access, wrong assumptions about classification. Confined route, water ingress, dust, possible hazardous area requirement. Emergency route mapping, ingress protection, maintainable linear fittings, classification check. L-Line Emergency / TB, ConV2 Emergency, SST Emergency, Emlux LED Emergency, hazardous options if required.
Stockpile / run of mine (ROM) / load out Uneven coverage over a large area, operator glare, poor vehicle visibility, spill light into adjacent areas. Rain, dust, wind, heat, pole or structure mounting, mobile equipment movement. Controlled optics, an aiming plan, glare management, service access and corrosion resistance where exposed. Turbo, Turbo.Mini, KL-Series, Ultra.
Workshop / plant room / switchroom Task areas underlit, emergency paths unclear, fittings not suited to heat or contamination. Indoor dust, heat, electrical infrastructure, maintenance work, outage requirements. Separate general, task and emergency lighting decisions, with task illuminance to AS/NZS 1680 and emergency lighting to AS/NZS 2293. L-Line / TB, KL-Series, Netsu, SST Emergency, Emlux LED Emergency.
How a review works

From a plant walkdown to a product shortlist.

A CHPP lighting project is more than a contact form. It follows a clear method that Eye Lighting can run across the whole site.

01

Map the plant zones

Split out conveyors, transfer stations, crushers, screens, tunnels, stockpile, load out, workshops and switchrooms.

02

Record the exposure

Note dust load, water, washdown, heat, corrosion, vibration, impact, mounting height and maintenance access.

03

Define the task

Work out whether the light supports walking, inspection, clean up, maintenance, vehicle movement, egress or security.

04

Confirm the constraints

Confirm illuminance targets to AS/NZS 1680, emergency escape lighting to AS/NZS 2293, hazardous area classification to AS/NZS 60079, and wiring to AS/NZS 3000, along with site material requirements.

Common questions

CHPP and fixed plant lighting questions.

Short answers to the questions site engineers, electrical contractors and planners ask most often.

What lighting does a coal handling and preparation plant need?

A CHPP needs different luminaires for each area. Conveyors and walkways suit pole mounted conveyor luminaires and sealed linears, transfer stations and crushers suit vibration rated floodlights, and reclaim tunnels need emergency rated fittings. Eye Lighting matches each zone to the right product rather than running one fitting across the whole site.

What IP and IK rating should CHPP lighting have?

Coal handling areas face heavy dust and washdown, so luminaires are usually specified to IP66 for ingress and IK08 or IK09 for impact. Eye Lighting fittings such as Turbo and KL-Series meet these ratings and are built to AS/NZS 60598.

How do you light a conveyor gallery safely?

Aim for continuous, even coverage along the full run rather than bright points with dark gaps between them. Control glare where fittings sit near eye level, and add emergency lighting wherever the gallery doubles as an escape route. The ConV and L-Line ranges are built for this duty.

Which luminaires suit crushers and screens?

Crushers and screens generate constant vibration that fatigues standard fittings. Specify vibration rated products with strong brackets and a sound driver strategy. The Turbo Series is tested to IEC 60068-2-6 at 3G across all three axes, delivers up to 90,000 lumens at 150 lm/W, and runs its driver remotely up to 60 metres from the machine with 25kA surge protection.

Do reclaim tunnels need emergency lighting?

Yes. Reclaim tunnels and enclosed routes carry a higher risk during an outage, so emergency escape lighting should be designed to AS/NZS 2293 and mapped as a continuous route. SST Emergency, Emlux LED Emergency, L-Line Emergency / TB and ConV2 Emergency all cover this duty.

Is hazardous area lighting required in a CHPP?

It depends on the site and its dust classification. Combustible coal dust is classified under AS/NZS 60079.10.2, and where a hazardous area is identified you use certified fittings such as BOYLE Xtrem. Confirm the classification before selecting equipment.

CHPP lighting support

Start with the plant area, then match the fitting.

Send the CHPP zone, mounting conditions, exposure and task. Eye Lighting will help narrow the shortlist across conveyor lighting, sealed linears, floodlighting, emergency fittings and harsh environment lighting solutions.