Explosion Proof
Lighting Australia
AU-HA04 LED Explosion-Proof Floodlight for Hazardous Locations
AU-HA04 is a hazardous-location LED floodlight for chemical, oil and gas, petrochemical, manufacturing, power generation, foundry, pulp and paper, waste and sewage treatment sites. Three wattage options cover 150W, 200W and 240W, with output up to 36,000 lm at 150 lm/W.
High-Output Floodlighting for Classified Industrial Sites
Explosion proof lighting in Australia must be selected against the site classification, installation conditions and maintenance requirements. AU-HA04 gives specifiers a high-output floodlight platform with hazardous-area certification markings and industrial construction details for demanding sites.
Hazardous Compliance
IECEx, ATEX and UL844 certification coverage includes Ex nR IIC T6/T5 Gc and Ex tb IIIC T80°C/95°C Db IP66 markings for hazardous-location floodlighting work.
High Output Range
Three model levels cover 22,500 lm, 30,000 lm and 36,000 lm, allowing output selection without moving away from the AU-HA04 floodlight platform.
Marine Grade Build
Marine grade construction, C4 corrosion resistance, tempered glass, anti-UV performance, stainless steel screws and copper-free aluminium support corrosive industrial environments.
Controlled Distribution
Twelve optical patterns, an optional visor and a precisely adjustable bracket support floodlighting layouts where spill control and aiming accuracy matter.
AU-HA04 for Hazardous Location Floodlighting
AU-HA04 is listed as a luminaire for use in hazardous locations. It is suited to industrial areas where vapours, gases, dust or combustible contaminants require site-specific hazardous area classification and compliant electrical installation.
The range supports Class I Division II, Class II Division I, Class II Division II and Class III certification context in the brochure, alongside IECEx and ATEX markings. For Australian work, installation and maintenance still need to follow local regulations, AS/NZS 60079 requirements and the site classification.
For searchers comparing explosion proof lighting Australia options, AU-HA04 gives the required balance of high lumen output, corrosion resistance, ingress protection and aiming control in a single floodlight series.
AU-HA04 Output Options
The AU-HA04 family is available in three wattage and lumen packages. All three share the IP66 and IK08 protection ratings.
AU-HA04-150
150W Model
Hazardous-location LED floodlight delivering 22,500 lm at 150 lm/W.
- Power150W
- Output22,500 lm
- Efficacy150 lm/W
AU-HA04-200
200W Model
Hazardous-location LED floodlight delivering 30,000 lm at 150 lm/W.
- Power200W
- Output30,000 lm
- Efficacy150 lm/W
AU-HA04-240
240W Model
Highest output AU-HA04 option, delivering 36,000 lm at 150 lm/W.
- Power240W
- Output36,000 lm
- Efficacy150 lm/W
| Model | Power | Luminous Flux | Efficacy | Input Voltage |
|---|---|---|---|---|
| AU-HA04-150 | 150W | 22,500 lm | 150 lm/W | 100-277Vac or 277-480Vac |
| AU-HA04-200 | 200W | 30,000 lm | 150 lm/W | 100-277Vac or 277-480Vac |
| AU-HA04-240 | 240W | 36,000 lm | 150 lm/W | 100-277Vac or 277-480Vac |
AU-HA04 Technical Data
Electrical and Optical
| Power | 150W / 200W / 240W |
| Luminous Flux | 22,500 lm / 30,000 lm / 36,000 lm |
| Efficacy | Up to 150 lm/W |
| CCT Options | 2000K, 3000K, 4000K, 5700K, 6500K plus wider listed options |
| Colour LED Options | Red, green, blue and amber |
| Surge Protection | Standard 10kV |
Mechanical and Environmental
| Ingress / Impact | IP66 / IK08 |
| Ambient Range | -40°C to +65°C |
| Corrosion | C4 corrosion resistant |
| Lens | Tempered glass, anti-UV, IK08 |
| Material | Copper-free aluminium material |
| Warranty | 5 years |
Mounting, Wiring and Control Points
Bracket Mounting
AU-HA04 is listed with bracket mounting for hazardous-location floodlighting projects.
±90° Adjustment
The bracket is stated as precisely adjustable across ±90° for aiming during installation.
Cable Entry
Cable entry options include 3/4" NPT or M25×1.5.
Loop-In / Loop-Out
Cable entry supports loop-in and loop-out installation where specified.
Optional Visor
The visor option is listed for reduced unwanted uplight and spill light.
Optional Wire Guard
A stainless steel guard is available where the fitting needs added physical protection.


Industrial Environments for AU-HA04
AU-HA04 is built for hazardous-location floodlighting across corrosive and high-demand industrial facilities.
Chemical
Hazardous-location floodlighting for chemical processing and storage environments.
Oil, Gas and Petrochemical
Floodlighting for classified petroleum and gas infrastructure areas.
Pulp and Paper
Lighting for industrial areas with process moisture, contaminants and maintenance demands.
Foundries
High-output lighting for heavy industrial foundry environments.
Manufacturing
Hazardous-area floodlighting for manufacturing operations and support zones.
Waste and Sewage Treatment
Corrosion-resistant floodlighting for treatment plants and related infrastructure.
Power Generation
Hazardous-location floodlighting for generation and utility plant areas.

Australian Hazardous-Area Floodlighting
The AU-HA range covers Zone 1, Zone 2 and 21/22 hazardous environments, with IECEx and AS/NZS 60079 certification across the range. AU-HA04 gives project teams a high-output floodlight option for hazardous-location work where the final luminaire selection must match the site classification.
Final selection depends on the site hazardous area classification, gas or dust group, temperature requirement, mounting method and electrical design. Eye Lighting Australia can support project teams with model selection against those requirements.
Ratings for Specification Review
AU-HA04 combines high lumen output with hazardous-area certification coverage, IP66 ingress protection, IK08 impact resistance, C4 corrosion resistance and a -40°C to +65°C ambient range.
Installation and maintenance must be carried out by licensed professionals in accordance with local regulations and the site-specific hazardous area classification.
Guard, Visor and Cable Entry Detail
Optional stainless steel guard and visor accessories, 3/4" NPT or M25×1.5 cable entry, loop-in and loop-out wiring, and bracket mounting with ±90° adjustment support site-specific installation needs.
The visor helps reduce unwanted uplight and spill light, while the wire guard provides added physical protection where required.
AU-HA04 Explosion Proof Lighting Questions
Is AU-HA04 suitable for explosion proof lighting in Australia?
AU-HA04 is listed as a luminaire for use in hazardous locations. Final suitability depends on the Australian site’s hazardous area classification, electrical design and installation requirements.
What output does AU-HA04 provide?
The range covers 22,500 lm on the 150W model, 30,000 lm on the 200W model and 36,000 lm on the 240W model.
What hazardous certifications apply?
AU-HA04 carries UL844, IECEx and ATEX certification coverage, including Ex nR IIC T6/T5 Gc and Ex tb IIIC T80°C/95°C Db IP66 markings.
What ingress and impact ratings does AU-HA04 carry?
AU-HA04 is listed with IP66 ingress protection and IK08 impact resistance.
What ambient temperature range applies?
The maximum operating ambient temperature range is -40°C to +65°C.
What mounting and cable entry details are listed?
AU-HA04 uses bracket mounting, with a precisely adjustable ±90° bracket. Cable entry options include 3/4" NPT or M25×1.5.
Are colour temperature options available?
White colour temperature options include 2000K, 3000K, 4000K, 5700K and 6500K, with additional CCT options and red, green, blue and amber LED options.
What accessories are available?
Optional stainless steel guard and visor accessories are available. The visor helps reduce unwanted uplight and spill light.
Hazardous-Area Lighting Support
Eye Lighting Australia supplies industrial lighting solutions for classified, corrosive and high-demand facilities across Australia. For AU-HA04 project work, the correct next step is to match the fitting against the site’s hazardous area classification and required output.
Project teams can use AU-HA04 where a certified floodlight is required for hazardous-location industrial environments, subject to site classification and installation design.

Specify AU-HA04 for Your Hazardous-Area Project
Contact Eye Lighting Australia to review AU-HA04 against your site classification, lumen requirement, mounting method and environmental exposure.
Contact Eye Lighting Australia