Flood Lights Anti Corrosive Australia Hades
High-output modular floodlighting for demanding environments
The Hades range combines C4 corrosion resistance, IP66 ingress protection, IK08 impact protection and five high-output models from 600W to 1800W.
Selecting High-Output Anti-Corrosive Flood Lights
Corrosion Resistance
Hades carries a C4 corrosion resistance rating and uses a low-copper aluminium alloy housing with powder coating.
Required Output
Five models provide up to 91,200 lm through to 277,200 lm for demanding large-area lighting designs.
Environmental Protection
IP66 ingress protection and IK08 mechanical impact protection are specified separately from corrosion resistance.
Aiming and Control
A stepless adjustment bracket supports accurate tilt adjustment, with optional 0-10V, DALI and DMX control.
Hades Floodlighting for Demanding Applications
Hades is a modular LED floodlight designed for industrial and open-area applications. Its individual module design supports continuous function, while the adjustable bracket and optional magnetic aiming device assist with positioning.
The range uses remote constant-current drivers and asymmetrical light distribution. Power options extend from 600W to 1800W, with maximum listed efficacy up to 154 lm/W across the model range.

Select the Hades Output for the Lighting Design
Hades 600 / 750
Compact Modular Options
600W and 750W models deliver up to 91,200 lm and 108,750 lm respectively.
View ProductHades 1200 / 1500
High Output Options
1200W and 1500W models deliver up to 183,600 lm and 220,500 lm respectively.
View ProductHades 1800
Maximum Range Output
The 1800W model delivers initial luminous flux up to 277,200 lm at up to 154 lm/W.
View ProductHades Technical Specifications
Electrical and Optical
| Input voltage | 200 to 420 Vac |
| Input frequency | 50/60 Hz |
| Power range | 600W, 750W, 1200W, 1500W, 1800W |
| Initial luminous flux | Up to 91,200 to 277,200 lm |
| Initial efficacy | Up to 145 to 154 lm/W by model |
| CCT | 4000K; optional 3000K and 5700K |
| CRI | Ra80; optional Ra70 and Ra90 |
| Distribution | Asymmetrical |
| Surge protection | 20kV |
| Control interface | Optional 0-10V / DALI / DMX |
Mechanical and Environmental
| Housing | Aluminium alloy, less than 0.01% copper |
| Optical cover | Tempered glass |
| Lens | Polycarbonate optical lens |
| Fasteners | Stainless steel screws |
| Ingress protection | IP66 |
| Impact protection | IK08 |
| Corrosion resistance | C4, ISO 9223:2012 |
| Protection class | Class I |
| Service life | 100,000 hours (L80) |
| Ambient temperature | -30°C to +40°C or +50°C by model |
Hades Model Range
| Model | Power | Initial luminous flux | Initial efficacy |
|---|---|---|---|
| Hades 600 | 600W | Up to 91,200 lm | Up to 152 lm/W |
| Hades 750 | 750W | Up to 108,750 lm | Up to 145 lm/W |
| Hades 1200 | 1200W | Up to 183,600 lm | Up to 153 lm/W |
| Hades 1500 | 1500W | Up to 220,500 lm | Up to 147 lm/W |
| Hades 1800 | 1800W | Up to 277,200 lm | Up to 154 lm/W |
Mounting, Aiming and Control Options
Stepless Adjustment
The mounting bracket supports accurate tilt adjustment for the required aiming position.
Magnetic Aiming Device
An aiming device and bracket are listed as an available accessory.
Stirrup Mount
A stirrup mounting bracket is available to fix the remote driver to the luminaire bracket.
Clamp Mount
A clamp mount bracket is available as a two-piece set.
Visor
A visor is available for the listed Hades lens configurations.
DALI / DMX Programmer
A programmer is listed for projects using the optional DALI or DMX interface.
Applications Listed for Hades
Eye Lighting lists Hades for demanding environments, hardstand areas, marine environments, airports and railway yards.
Demanding Environments
High-output modular construction supports selection for demanding large-area applications.
Hardstand Areas
Asymmetrical distribution and five outputs support photometric selection for hardstand areas.
Marine Environments
C4 corrosion resistance is specified separately from the IP66 and IK08 protection ratings.
Airports
Airports are included in Eye Lighting's listed applications for Hades.
Railway Yards
Railway yards are included in the Hades product application list.
Industrial Open Areas
The Hades brochure describes the range for industrial and open-area applications.

Five Models from 600W to 1800W
The Hades range provides a progression from 91,200 lm to 277,200 lm. Each model uses a remote constant-current driver and operates from a 200 to 420 Vac supply.
Model selection must consider the photometric layout, mounting geometry, ambient temperature and electrical requirements of the project.
Verified Product Compliance and Protection Ratings
The Hades documentation lists AS/NZS 60598 safety compliance, AS/NZS CISPR15 EMC compliance, RCM marking and RoHS compliance.
IP66, IK08 and C4 address different aspects of the product specification. Each rating should be assessed against the actual operating environment and project requirements.

Selecting Hades for Corrosive Environments
What corrosion resistance rating does Hades carry?
Hades carries a C4 corrosion resistance rating to ISO 9223:2012.
What output options are available?
Five models cover 600W, 750W, 1200W, 1500W and 1800W, with initial luminous flux up to 91,200 lm through to 277,200 lm.
What ingress and impact ratings apply?
The Hades range is rated IP66 for ingress protection and IK08 for mechanical impact protection.
Which applications are listed?
Eye Lighting lists demanding environments, hardstand areas, marine environments, airports and railway yards.
What is the operating temperature range?
Depending on the model, the listed upper ambient limit is +40°C or +50°C. All five models list a lower limit of -30°C.
What control options are available?
The technical specification lists optional 0-10V, DALI and DMX control interfaces.
How is the floodlight aimed?
A stepless adjustment bracket supports accurate tilt adjustment, and a magnetic aiming device is listed among the product features.
Which compliance standards are listed?
The product documentation lists AS/NZS 60598 safety compliance, AS/NZS CISPR15 EMC compliance, RCM marking and RoHS compliance.
Application Engineering for High-Output Floodlighting
Eye Lighting Australia supplies industrial and commercial lighting solutions for demanding Australian applications. Hades provides five high-output models, asymmetrical distribution and a range of mounting and control options.
Eye Lighting Australia can provide certified photometric data, technical support and Application Engineering to assist with model selection, layout and specification.

Review Hades for Your Application
Contact Eye Lighting Australia to review the required output, distribution, mounting arrangement and environmental conditions for your project.
Contact Eye Lighting Australia