LED High Bay Lighting Australia | AU-HA05 and AU-HA08 | Eye Lighting Australia
IECEx • ATEX • AS/NZS 60079

LED High Bay Lighting Australia

AU-HA05 and AU-HA08 hazardous-area high bay comparison

Australian high bay projects in hazardous areas need more than output. The selected luminaire must match the site classification, mounting method, emergency requirement and environmental exposure. AU-HA05 and AU-HA08 cover two different high bay roles inside Eye Lighting Australia’s AU-HA hazardous range.

Zone 2Zone 1IP66C4Emergency option
AU-HA05 hazardous-area LED high bay
33,600 lm
AU-HA05 Maximum
Zone 1
AU-HA08 Context
IP66
Both High Bays
IK10
AU-HA08 Impact
5 Years
Standard Warranty

High Bay Lighting Matched to Area Classification

The AU-HA range covers Zone 1, Zone 2, Zone 21 and Zone 22 hazardous environments. AU-HA05 and AU-HA08 give specifiers two high bay paths for different classification and emergency requirements.

01

Zone 2 High Bay

AU-HA05 is listed as an LED explosion-proof highbay light for Zone 2 and C1D2 hazardous areas.

02

Zone 1 Emergency High Bay

AU-HA08 is a high bay with emergency function and Ex db IIC T6 Gb certification marking.

03

Industrial Output Range

AU-HA05 spans 30W to 240W and 4,200 lm to 33,600 lm for higher-output hazardous-area high bay layouts.

04

Emergency Runtime

AU-HA08 provides 6W emergency lighting for 3 hours or 12W for 1.5 hours, with 24-hour charging time.

High Bay Output for Classified Industrial Areas

AU-HA05 is the broader output high bay in this pair. It covers nine wattage levels from 30W to 240W, with listed luminous flux from 4,200 lm to 33,600 lm and efficacy of at least 140 lm/W.

It is suited to Zone 2 and C1D2 high bay work where output, mounting flexibility and industrial construction need to be reviewed against site conditions.

AU-HA05 high bay product render
AU-HA08 high bay emergency product render

AU-HA08 for Zone 1 Emergency Contexts

AU-HA08 is an LED explosion-proof highbay light with emergency function. Its IECEx and ATEX markings include Ex db IIC T6 Gb and Ex tb IIIC T80°C Db IP66.

The range covers 30W to 100W with IP66 and IK10 protection ratings. Emergency operation is listed as 6W for 3 hours or 12W for 1.5 hours.

AU-HA05 and AU-HA08 High Bay Options

The two high bays should not be treated as interchangeable. Selection depends on zone classification, output, emergency operation and mounting requirements.

AU-HA05

Zone 2 / C1D2 High Bay

Broad-output hazardous-area high bay for Zone 2 work.

  • Power30W to 240W
  • Output4,200 to 33,600 lm
  • ProtectionIP66 / IK08

AU-HA08

Zone 1 Emergency High Bay

Compact emergency high bay for hazardous-area lighting projects.

  • Power30W to 100W
  • Emergency6W / 3h or 12W / 1.5h
  • ProtectionIP66 / IK10

AU-HA Range

Hazardous-Area Context

Eye Lighting’s AU-HA range covers high bay, low bay, floodlight, linear batten, junction box, streetlight and emergency Lighting Solutions.

  • Zones1, 2, 21, 22
  • MaterialsMarine-grade aluminium
  • CorrosionC4
AU-HA05 transparent product render
AU-HA08 transparent product render

AU-HA05 and AU-HA08 Specification Summary

AU-HA05

TypeLED explosion-proof highbay light for Zone 2 and C1D2
Power30W / 50W / 75W / 100W / 120W / 150W / 180W / 200W / 240W
Luminous Flux4,200 lm to 33,600 lm
EfficacyAt least 140 lm/W
ProtectionIP66 / IK08
Ambient Range-40°C to +65°C

AU-HA08

TypeLED explosion-proof highbay light with emergency function
Power30W / 40W / 50W / 60W / 75W / 100W
Luminous FluxRa70 listed ranges from 4,244 lm to 14,751 lm
Efficacy150 lm/W non-emergency; 180 lm/W emergency
ProtectionIP66 / IK10
Emergency6W for 3 hours or 12W for 1.5 hours
AU-HA05 vs AU-HA08 Comparison
Selection PointAU-HA05AU-HA08
Primary roleZone 2 / C1D2 high bay with broad output rangeZone 1 high bay with emergency function
Certification markingsEx nR IIC T6/T5 Gc; Ex tb IIIC T80°C/T95°C Db IP66Ex db IIC T6 Gb; Ex tb IIIC T80°C Db IP66
Power range30W to 240W30W to 100W
MountingPendant, ceiling, wall, trunnion, 25° stanchion, 90° stanchionCeiling, pendant, trunnion, wall bracket, 25° stanchion
Emergency functionAU-HA05-050 emergency backup option listedEmergency function is core to the range

Mounting and Wiring Points

AU-HA05 Pendant

3/4" NPT, 1" NPT, M25×1.5 or M20×1.5 entry listed.

AU-HA05 Stanchion

25° and 90° stanchion mounting options are listed.

AU-HA05 Trunnion

Trunnion mounting is available for high bay positioning.

AU-HA08 Quick Connect

The mounting module can be installed and wired before the luminaire is screwed in.

AU-HA08 Cable Entries

Multiple cable entries support interconnection and installation wiring.

Emergency Batteries

AU-HA08 lists LiFePO4 or Ni-Cd battery options for backup power.

Industrial Areas Where High Bays Are Reviewed

Final suitability depends on the site’s hazardous area classification, gas or dust group, mounting height, task plane and electrical design.

Hazardous Process Areas

High bay lighting where classified gases or vapours affect luminaire selection.

Industrial High Bays

Large indoor or sheltered industrial areas that need compliant overhead illumination.

Marine Industrial Sites

AU-HA range materials support corrosive marine and industrial environments.

Dust Hazard Areas

AU-HA markings include dust context for Zone 21/22 review where applicable.

Emergency Egress

AU-HA08 adds emergency lighting where backup output is required.

Australian Project Upgrades

Model selection should be checked against AS/NZS 60079 and site classification.

Selection Must Follow the Site Classification

The AU-HA range sheet states that hazardous-area luminaires must be installed and maintained by licensed professionals in accordance with local regulations and site-specific hazardous area classifications.

For Australian projects, AU-HA05 and AU-HA08 should be compared against zone classification, emergency operation, high bay output, mounting method, cable entry and environmental exposure before specification.

AU-HA08 emergency high bay product render

LED High Bay Lighting Australia Questions

Which Eye Lighting high bay is listed for Zone 2?

AU-HA05 is listed as an LED explosion-proof highbay light for Zone 2 and C1D2.

Which high bay includes emergency function?

AU-HA08 is listed as an LED explosion-proof highbay light with emergency function.

What output does AU-HA05 cover?

AU-HA05 covers 4,200 lm to 33,600 lm across 30W to 240W models.

What emergency runtime does AU-HA08 list?

AU-HA08 provides 6W of emergency lighting for 3 hours or 12W for 1.5 hours.

What protection ratings apply?

AU-HA05 is listed as IP66 and IK08. AU-HA08 is listed as IP66 and IK10.

What does the AU-HA range cover?

The AU-HA range covers Zone 1, Zone 2, Zone 21 and Zone 22 hazardous environments.

Are mounting options available?

Yes. AU-HA05 and AU-HA08 both list multiple mounting options for site-specific installation.

Who should confirm final selection?

Final selection should be checked against the site classification and electrical design by qualified project personnel.

Hazardous-Area High Bay Support

Eye Lighting Australia supplies industrial Lighting Solutions for classified, corrosive and high-demand sites. AU-HA05 and AU-HA08 give project teams two source-backed high bay options for hazardous-area review.

For a project-specific recommendation, provide the zone classification, gas or dust group, required output, mounting method and emergency lighting requirement.

AU-HA05 high bay product render

Compare AU-HA05 and AU-HA08 for Your Site

Contact Eye Lighting Australia to review hazardous-area high bay Lighting Solutions against your site classification, output requirement and emergency lighting need.

Contact Eye Lighting Australia