LED High Bay Lighting Australia
AU-HA05 and AU-HA08 hazardous-area high bay comparison
Australian high bay projects in hazardous areas need more than output. The selected luminaire must match the site classification, mounting method, emergency requirement and environmental exposure. AU-HA05 and AU-HA08 cover two different high bay roles inside Eye Lighting Australia’s AU-HA hazardous range.
High Bay Lighting Matched to Area Classification
The AU-HA range covers Zone 1, Zone 2, Zone 21 and Zone 22 hazardous environments. AU-HA05 and AU-HA08 give specifiers two high bay paths for different classification and emergency requirements.
Zone 2 High Bay
AU-HA05 is listed as an LED explosion-proof highbay light for Zone 2 and C1D2 hazardous areas.
Zone 1 Emergency High Bay
AU-HA08 is a high bay with emergency function and Ex db IIC T6 Gb certification marking.
Industrial Output Range
AU-HA05 spans 30W to 240W and 4,200 lm to 33,600 lm for higher-output hazardous-area high bay layouts.
Emergency Runtime
AU-HA08 provides 6W emergency lighting for 3 hours or 12W for 1.5 hours, with 24-hour charging time.
High Bay Output for Classified Industrial Areas
AU-HA05 is the broader output high bay in this pair. It covers nine wattage levels from 30W to 240W, with listed luminous flux from 4,200 lm to 33,600 lm and efficacy of at least 140 lm/W.
It is suited to Zone 2 and C1D2 high bay work where output, mounting flexibility and industrial construction need to be reviewed against site conditions.

AU-HA08 for Zone 1 Emergency Contexts
AU-HA08 is an LED explosion-proof highbay light with emergency function. Its IECEx and ATEX markings include Ex db IIC T6 Gb and Ex tb IIIC T80°C Db IP66.
The range covers 30W to 100W with IP66 and IK10 protection ratings. Emergency operation is listed as 6W for 3 hours or 12W for 1.5 hours.
AU-HA05 and AU-HA08 High Bay Options
The two high bays should not be treated as interchangeable. Selection depends on zone classification, output, emergency operation and mounting requirements.
AU-HA05
Zone 2 / C1D2 High Bay
Broad-output hazardous-area high bay for Zone 2 work.
- Power30W to 240W
- Output4,200 to 33,600 lm
- ProtectionIP66 / IK08
AU-HA08
Zone 1 Emergency High Bay
Compact emergency high bay for hazardous-area lighting projects.
- Power30W to 100W
- Emergency6W / 3h or 12W / 1.5h
- ProtectionIP66 / IK10
AU-HA Range
Hazardous-Area Context
Eye Lighting’s AU-HA range covers high bay, low bay, floodlight, linear batten, junction box, streetlight and emergency Lighting Solutions.
- Zones1, 2, 21, 22
- MaterialsMarine-grade aluminium
- CorrosionC4
AU-HA05 and AU-HA08 Specification Summary
AU-HA05
| Type | LED explosion-proof highbay light for Zone 2 and C1D2 |
| Power | 30W / 50W / 75W / 100W / 120W / 150W / 180W / 200W / 240W |
| Luminous Flux | 4,200 lm to 33,600 lm |
| Efficacy | At least 140 lm/W |
| Protection | IP66 / IK08 |
| Ambient Range | -40°C to +65°C |
AU-HA08
| Type | LED explosion-proof highbay light with emergency function |
| Power | 30W / 40W / 50W / 60W / 75W / 100W |
| Luminous Flux | Ra70 listed ranges from 4,244 lm to 14,751 lm |
| Efficacy | 150 lm/W non-emergency; 180 lm/W emergency |
| Protection | IP66 / IK10 |
| Emergency | 6W for 3 hours or 12W for 1.5 hours |
| Selection Point | AU-HA05 | AU-HA08 |
|---|---|---|
| Primary role | Zone 2 / C1D2 high bay with broad output range | Zone 1 high bay with emergency function |
| Certification markings | Ex nR IIC T6/T5 Gc; Ex tb IIIC T80°C/T95°C Db IP66 | Ex db IIC T6 Gb; Ex tb IIIC T80°C Db IP66 |
| Power range | 30W to 240W | 30W to 100W |
| Mounting | Pendant, ceiling, wall, trunnion, 25° stanchion, 90° stanchion | Ceiling, pendant, trunnion, wall bracket, 25° stanchion |
| Emergency function | AU-HA05-050 emergency backup option listed | Emergency function is core to the range |
Mounting and Wiring Points
AU-HA05 Pendant
3/4" NPT, 1" NPT, M25×1.5 or M20×1.5 entry listed.
AU-HA05 Stanchion
25° and 90° stanchion mounting options are listed.
AU-HA05 Trunnion
Trunnion mounting is available for high bay positioning.
AU-HA08 Quick Connect
The mounting module can be installed and wired before the luminaire is screwed in.
AU-HA08 Cable Entries
Multiple cable entries support interconnection and installation wiring.
Emergency Batteries
AU-HA08 lists LiFePO4 or Ni-Cd battery options for backup power.
Industrial Areas Where High Bays Are Reviewed
Final suitability depends on the site’s hazardous area classification, gas or dust group, mounting height, task plane and electrical design.
Hazardous Process Areas
High bay lighting where classified gases or vapours affect luminaire selection.
Industrial High Bays
Large indoor or sheltered industrial areas that need compliant overhead illumination.
Marine Industrial Sites
AU-HA range materials support corrosive marine and industrial environments.
Dust Hazard Areas
AU-HA markings include dust context for Zone 21/22 review where applicable.
Emergency Egress
AU-HA08 adds emergency lighting where backup output is required.
Australian Project Upgrades
Model selection should be checked against AS/NZS 60079 and site classification.
Selection Must Follow the Site Classification
The AU-HA range sheet states that hazardous-area luminaires must be installed and maintained by licensed professionals in accordance with local regulations and site-specific hazardous area classifications.
For Australian projects, AU-HA05 and AU-HA08 should be compared against zone classification, emergency operation, high bay output, mounting method, cable entry and environmental exposure before specification.
LED High Bay Lighting Australia Questions
Which Eye Lighting high bay is listed for Zone 2?
AU-HA05 is listed as an LED explosion-proof highbay light for Zone 2 and C1D2.
Which high bay includes emergency function?
AU-HA08 is listed as an LED explosion-proof highbay light with emergency function.
What output does AU-HA05 cover?
AU-HA05 covers 4,200 lm to 33,600 lm across 30W to 240W models.
What emergency runtime does AU-HA08 list?
AU-HA08 provides 6W of emergency lighting for 3 hours or 12W for 1.5 hours.
What protection ratings apply?
AU-HA05 is listed as IP66 and IK08. AU-HA08 is listed as IP66 and IK10.
What does the AU-HA range cover?
The AU-HA range covers Zone 1, Zone 2, Zone 21 and Zone 22 hazardous environments.
Are mounting options available?
Yes. AU-HA05 and AU-HA08 both list multiple mounting options for site-specific installation.
Who should confirm final selection?
Final selection should be checked against the site classification and electrical design by qualified project personnel.
Hazardous-Area High Bay Support
Eye Lighting Australia supplies industrial Lighting Solutions for classified, corrosive and high-demand sites. AU-HA05 and AU-HA08 give project teams two source-backed high bay options for hazardous-area review.
For a project-specific recommendation, provide the zone classification, gas or dust group, required output, mounting method and emergency lighting requirement.
Compare AU-HA05 and AU-HA08 for Your Site
Contact Eye Lighting Australia to review hazardous-area high bay Lighting Solutions against your site classification, output requirement and emergency lighting need.
Contact Eye Lighting Australia