Explosion proof and flameproof LED lighting for hazardous industrial sites.
AU-HA hazardous area luminaires for Australian sites where gas, dust, corrosion, emergency lighting and certified installation requirements define the specification.
Hazardous area lighting for gas, dust and process risk.
Explosion proof, flameproof, Zone 1 and Zone 2 lighting should be specified from the classified area, gas or dust group, ambient temperature and installation method.

Process areas, pump stations, loading bays and tank farms where explosive gas atmospheres may be present.

Coal handling, conveyors and processing plant where dust, corrosion and maintenance access shape the luminaire specification.

Chemical storage, mixing and packaging areas where the zone classification and site atmosphere set the specification.

Silos, mills, feed processing and storage areas where combustible dust can require Zone 21 or Zone 22 lighting.
Classify the area before selecting the luminaire.
The right hazardous area luminaire is selected from the site classification first. Zone rating, gas or dust atmosphere, protection concept, temperature limit, corrosion exposure and emergency requirement all need to align.
AU-HA hazardous area luminaires cover Zone 1 flameproof high bay, Zone 2 gas lighting, Zone 21/22 dust lighting, hazardous floodlighting, high bay and low bay formats. AU-HA06 is available for Zone 2 gas and Zone 22 dust linear applications. AU-HA luminaires are IECEx certified and support AS/NZS 60079 compliance when selected against the current datasheet and site classification.
Classify the zone
Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 classifications define the gas or dust risk and narrow the suitable protection concepts.
Separate gas from dust
Gas atmospheres and combustible dust environments use different markings. Some AU-HA solutions cover both, but only within their certified scope.
Allow for site conditions
Corrosion, housing material, emergency backup and maintenance access can matter as much as output.
Five site factors that shape the lighting schedule.
Resolve these early so the lighting schedule matches the certification, environment and maintenance reality of the site.

Flameproof LED lighting for Zone 1 gas and Zone 21 dust areas.
Zone 1 areas need luminaires certified for explosive gas atmospheres that are likely during normal operation. AU-HA08 uses Ex db flameproof construction and includes integrated emergency options.
- Zone 1 and Zone 2 gas environments.
- Zone 21 and Zone 22 combustible dust areas.
- High bay lighting where flameproof Ex db certification is required.
Suitable AU-HA luminaire: AU-HA08 Explosion-Proof Highbay.
Explosion proof lights for Zone 2 gas and C1D2 areas.
Zone 2 lighting is used where an explosive gas atmosphere is not expected during normal operation, or would occur only briefly. AU-HA Zone 2 options include floodlight, high bay, low bay and linear formats.
- Oil, gas, chemical, paint and process areas.
- Hazardous high bay, low bay, linear and floodlight layouts.
- Marine, coastal and corrosive industrial environments.
Suitable AU-HA luminaires: AU-HA04, AU-HA05, AU-HA06 and AU-HA10.


Hazardous LED lighting for combustible dust environments.
Dust classified areas need luminaires selected against the Zone 21 or Zone 22 marking, ingress protection, surface temperature and maintenance access. These requirements apply across mining, CHPP, grain, feed, pulp and process facilities.
- Combustible dust handling, transfer and storage.
- Coal, grain, feed, paper and process environments.
- Flood, high bay, low bay and linear lighting formats.
Suitable AU-HA luminaires: AU-HA04, AU-HA05, AU-HA08 and AU-HA10 for Zone 21/22 dust applications; AU-HA06 for Zone 22 dust linear applications.
Match the AU-HA solution to the certified zone.
Eye Lighting can match the certified zone, atmosphere and mounting requirement to the correct AU-HA luminaire.
AU-HA hazardous area lighting solutions.
Floodlight, high bay, low bay and linear formats for certified gas and dust classified areas.

AU-HA04 Explosion-Proof Floodlight
Zone 2, 21 and 22 floodlight. 150W to 240W, up to 36,000 lm, adjustable bracket, IP66, IK08 and C4 corrosion resistance.
Zone 2 gas · Zone 21/22 dust · floodlighting
AU-HA05 Explosion-Proof Highbay
Zone 2, 20, 21 and 22 high bay plus Class I Div 2. 30W to 240W, 4,200 to 33,600 lm, up to 140 lm/W and six mounting configurations.
Zone 2 gas · Zone 20/21/22 dust · high bay
AU-HA06 Explosion-Proof Linear Light
Zone 2 and Zone 22 linear light. 20W to 100W, up to 16,000 lm, 160 lm/W, IP66, IK08, marine-grade construction and optional emergency backup.
Zone 2 gas · Zone 22 dust · linear walkways
AU-HA08 Explosion-Proof Highbay
Ex db flameproof high bay for Zone 1, 2, 21 and 22. 30W to 100W, up to 150 lm/W, IP66, IK10 and integrated emergency options.
Zone 1 gas · Zone 21/22 dust · emergency
AU-HA10 Explosion-Proof Low Bay
Zone 2, 21 and 22 low bay. 160 lm/W, IP66, -40 to +65°C, selectable output and emergency option under the certified configuration.
Zone 2 gas · Zone 21/22 dust · low bayMatch each classified area to the correct AU-HA luminaire.
Use this matrix to narrow the AU-HA options before checking the current datasheet, installation method and site classification.
| Zone classification | What's present | Protection type | AU-HA solution |
|---|---|---|---|
| Zone 1 gas | Explosive gas atmosphere likely during normal operation. | Flameproof Ex db construction for higher-risk gas areas. | AU-HA08. |
| Zone 2 gas | Explosive gas atmosphere not expected in normal operation, or present briefly. | Non-sparking / restricted breathing styles where certified for Zone 2. | AU-HA04, AU-HA05, AU-HA06, AU-HA10. |
| Zone 20 dust | Combustible dust atmosphere present continuously or for long periods. | Dust-protected hazardous high bay where certified for Zone 20. | AU-HA05. |
| Zone 21 dust | Combustible dust atmosphere likely during normal operation. | Dust ignition protection matched to surface temperature and IP rating. | AU-HA04, AU-HA05, AU-HA08, AU-HA10. |
| Zone 22 dust | Combustible dust atmosphere not likely in normal operation, or present briefly. | Certified dust-protected flood, high bay, low bay or linear formats. | AU-HA04, AU-HA05, AU-HA06, AU-HA10. |
| Emergency hazardous lighting | Classified areas requiring backup illumination for egress or process safety. | Emergency version within the certified operating range and battery configuration. | AU-HA05, AU-HA08, AU-HA06, AU-HA10. |
Explosion proof, flameproof and Zone lighting questions.
Practical answers for facility managers, engineers and contractors planning hazardous area lighting in Australia.
What is explosion proof lighting?
Explosion proof lighting refers to luminaires certified for hazardous locations where flammable gas, vapour or combustible dust may be present. The correct AU-HA solution depends on the site classification, such as Zone 1, Zone 2, Zone 21 or Zone 22.
What is the difference between Zone 1 and Zone 2 lights?
Zone 1 applies where an explosive gas atmosphere is likely during normal operation. Zone 2 applies where it is not expected during normal operation, or only occurs briefly. AU-HA08 is the AU-HA flameproof high bay for Zone 1 gas, while AU-HA04, AU-HA05, AU-HA06 and AU-HA10 cover certified Zone 2 applications within their datasheets.
What does flameproof mean?
Flameproof, often marked Ex db, means the luminaire enclosure is designed to contain an internal explosion and prevent flame transmission to the surrounding hazardous atmosphere. AU-HA08 uses flameproof Ex db construction for Zone 1 gas environments.
What is the difference between gas and dust zones?
Gas zones relate to flammable gases or vapours. Dust zones relate to combustible dust atmospheres, such as grain, coal, flour, feed or process dust. A luminaire must be checked for the relevant gas or dust marking before use.
Which AU-HA solution suits which zone?
AU-HA08 suits Zone 1 gas and Zone 21/22 dust applications. AU-HA04, AU-HA05 and AU-HA10 cover Zone 2 gas and Zone 21/22 dust applications where their current datasheets list the required certification. AU-HA06 is listed for Zone 2 gas and Zone 22 dust linear applications.
Do AU-HA hazardous lights carry emergency versions?
AU-HA08 has integrated emergency options. AU-HA05 lists a 50W emergency model, while AU-HA06 and AU-HA10 list optional emergency configurations. Emergency versions must be selected against the certified temperature range, battery duration and site requirements.
Start with the zone, then match the AU-HA solution.
Send the site classification, gas or dust risk, mounting height, ambient temperature, corrosion exposure and emergency lighting requirement. Eye Lighting can identify the AU-HA options that suit the specification.